CODE:Remote Control


                 
HPRCA                                                                        HPRCB
1 receiver + 2 emitter (portable)

                  
HPRCB1 (One Channel)                                          HPRCB5 (Five Channel)
1 receiver + 1 emitter (box stand)
                 
HPRCC                                                                        HPRCD
1 receiver + 2 emitter (portable)                             1 receiver + 2 emitter (portable)

                  
HPRCE (Build-in)                                                         HPRCF
1 receiver + 1 emitter (box stand)                           1 receiver + 2 emitter (portable)

                   
HPRCG                                                                        HPRCH
1 receiver + 2 emitter (portable)                             1 receiver + 2 emitter (portable)


The Controller
was transfered by radio frequency of 433.92MHz. Limited transfering range is 70 meters through clearing air and it is 30 meters at least through double reinforced concreted wall.
Operation of Receiver
1     Configuring Code Setting
1.1    Select the channel of the emitter to be configured.
1.2     Turn on the power of the receiver and there will be prompting sounds from the buzzer (5 prompts with 1 second interval), at this time the receiver is ready for configuring. If no action taken to the receiver, it will be restore to the original status.
1.3     Push the “UP” button, if it’s 3 times of prompts continuously with 0.5 second interval, that is the first configuring code was completed setting. If add more configuring codes to the emitter, please conduct the following step.
1.4     Keep 5 seconds pushing the “STOP” button on the configured emitter till the prompting sounds (5 prompts with 1 second interval) happened, this time the receiver is ready for setting (around 5 seconds), then push a new emitter’s “UP” button, if there were 3 prompts from the receiver with 0.5 second interval,that means the new emitter was configuired successfully.
If add more emitters, please repeat the above step. Attention: The maximum channel number of emitter is 10 to be configuired for one receiver, if set more code, the 11th will replace the first configuired code.
2     Channel Memory Clearing
   
Keep pushing the “STOP” button for 5 seconds on the configured emitter till the prompts happened from the receiver (5 prompts with 1 second interval), then release the “STOP” button, this time the receiver was in ready status for setting (around 5 seconds), then push down “DEL” key at the back of the emitter, if there were 3 prompts come from the buzzer (with 0.5 second interval), that means all the channel memory of configuring code were cleared.
3     Direction Changing Setting
   
Direction Changing in the emitter (All following stepswere conducted under configured status.)Keep pushing the “STOP” button for 5 seconds in the completed configuration emitter till the prompts come out from the buzzer. 5 prompts with 1 second interval and release the “STOP” button, the receiver was ready for setting (around 5 seconds). Then push the “DOWN” button if 3 prompts with 0.5 seconds interval come from the buzzer, that means the direction was changed successfully. Repeating is restore to the original status.
4    Manual Control Setting(All following steps were conducted under configured status.)
   
Keep pushing the “STOP” button for 5 seconds in the completed configuration emitter till the prompts come out from the buzzer (5 prompts with 1 second interval), then release. At this time the receiver was ready for setting (around 5 seconds). At the same time to push the “STOP” button, if 3 prompts with 0.5 seconds interval come from the buzzer, that means within 1.5 seconds, the order from “UP” or “DOWN” button in emitter is also for manual control stage. If the pressing 1.5 seconds or more, after releasing the button motor will run continuously then. Repeating is to return to original status.
5    For emitter, we have single channel, four channels and five channels for option. Each flashlight represents one channel of the emitter. Push the “Select” button, the flashlight will be on, re-press the button to next channel, and so on, till the suitable channel, release the button and Channel was selected then. If all lights were on, that means the “Group Controlled” function ready.
    
The battery of the emitter is 12V23A. The method of changing battery is : open the battery cover in the back side, the battery position is visible, close the battery cover after changing the battery, all configuration will be original status.

 